WEKO3
アイテム
Cube 型ボス供試体の開発
https://iot.repo.nii.ac.jp/records/126
https://iot.repo.nii.ac.jp/records/1266fe16950-6864-4ef8-9734-7603e870a1b7
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-06-07 | |||||
タイトル | ||||||
タイトル | Cube 型ボス供試体の開発 | |||||
タイトル | ||||||
タイトル | Development of Cube Mold for Boss Specimen | |||||
言語 | en | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Concrete | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Non-destructive testing | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | BOSS specimen | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Placing | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Compressive strength | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Concrete | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Non-destructive testing | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | BOSS specimen | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Placing | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Compressive strength | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
菊田, 弘之
× 菊田, 弘之× 澤本, 武博× 篠崎, 徹× 森濱, 和正× 袴谷, 秀幸× KIKUTA, Hiroyuki× SAWAMOTO, Takehiro× SHINOZAKI, Toru× MORIHAMA, Kazumasa× HAKAMAYA, Hideyuki |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | As a method of estimating the strength of structure concrete, the core specimen is generally used. If the method of core specimen is used, the damage to the structure and the necessity for repair will arise. Therefore, the BOSS specimen with little damage to the structure was devised, and it has been a standard for NDIS number 3424. However, the present BOSS specimen is a 100×100×200mm prism, it does not correspond to ISO. In this study, the BOSS specimen which size was 100×100×100mm cube was devised, and the effect of form of BOSS Specimen on compressive strength of concrete was investigated. As a result, the placing of fresh concrete to the cube BOSS specimen was good, and the standard deviation of compressive strength of concrete was also small. |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 本研究では,100×100×100 ㎜のCube 型のボス供試体(Cube ボス供試体)を開発し,現在使用されているボス供試体とのコンクリートの充てん性および強度特性について比較検討を行った. | |||||
書誌情報 |
ものつくり大学紀要 en : The Bulletin of Institute of Technologists 号 4, p. 33-38, 発行日 2013 |
|||||